Host options and settings for IBM XIV systems

You must use specific settings to identify Lenovo Storage V series clustered systems as hosts to IBM® XIV® Storage System systems.

An XIV® Nextra™ host is a single WWPN, so one XIV® Nextra™ host must be defined for each Lenovo Storage V series node port in the clustered system. An XIV® Nextra™ host is considered to be a single SCSI initiator. Up to 256 XIV® Nextra™ hosts can be presented to each port. Each Lenovo Storage V series host object that is associated with the XIV® Nextra™ system must be associated with the same XIV® Nextra™ LUN map because each LU can only be in a single map.

An IBM® XIV® Storage System Type Number 2810 host can consist of more than one WWPN. Configure each Lenovo Storage V series node as an IBM® XIV® Storage System Type Number 2810 host and create a cluster of IBM® XIV® Storage System systems that corresponds to each of the Lenovo Storage V series nodes in the Lenovo Storage V series system.

Table 1 lists the host options and settings that can be changed using the IBM® XIV® Storage System and XIV® Nextra™ Storage Management GUI.

Table 1. IBMXIV Type Number 2810 and XIVNextra host options and required settings
Option Data type Range IBM® XIV® Storage System Type Number 2810 and XIV® Nextra™ default setting Lenovo Storage V series required setting Notes
Type Enum FC/iSCSI Not applicable FC The Type must be FC for Lenovo Storage V series.
XIV® Nextra™ map_set_special_type CLI command or IBM® XIV® Storage System Type Number 2810 special_type_set CLI command Enum default/hpux default default This command is used by hpux hosts only. Do not use the command for Lenovo Storage V series LUNs.
WWPN int64 Any Not applicable Node port For XIV® Nextra™, one host for each node port WWPN in the clustered system must be defined. For IBM® XIV® Storage System, Type Number 2810 one host port for each node port WWPN in the clustered system must be defined.
LUN Map String Any Not applicable Any For XIV® Nextra™, each Lenovo Storage V series host in the XIV® Nextra™ system must be associated with the same LUN map because each LU can be only in a single map.