Management GUI interface

The management GUI is a browser-based GUI for configuring and managing all aspects of your system. It provides extensive facilities to help troubleshoot and correct problems.

You use the management GUI to manage and service your system. The Monitoring > Events panel provides access to problems that must be fixed and maintenance procedures that step you through the process of correcting the problem.

The information on the Events panel can be filtered three ways:
Recommended action (default)
Shows only the alerts that require attention and have an associated fix procedure. Alerts are listed in priority order and should be fixed sequentially by using the available fix procedures. For each problem that is selected, you can:
  • Run a fix procedure.
  • View the properties.
Unfixed messages and alerts
Displays only the alerts and messages that are not fixed. For each entry that is selected, you can:
  • Run a fix procedure on any alert with an error code.
  • Mark an event as fixed.
  • Filter the entries to show them by specific minutes, hours, or dates.
  • Reset the date filter.
  • View the properties.
Show all
Displays all event types whether they are fixed or unfixed. For each entry that is selected, you can:
  • Run a fix procedure on any alert with an error code.
  • Mark an event as fixed.
  • Filter the entries to show them by specific minutes, hours, or dates.
  • Reset the date filter.
  • View the properties.

Some events require a certain number of occurrences in 25 hours before they are displayed as unfixed. If they do not reach this threshold in 25 hours, they are flagged as expired. Monitoring events are below the coalesce threshold and are usually transient.

You can also sort events by time or error code. When you sort by error code, the most serious events, those with the lowest numbers, are displayed first. You can select any event that is listed and select Actions > Properties to view details about the event.

  • Recommended Actions. For each problem that is selected, you can:
    • Run a fix procedure.
    • View the properties.
  • Event log. For each entry that is selected, you can:
    • Run a fix procedure.
    • Mark an event as fixed.
    • Filter the entries to show them by specific minutes, hours, or dates.
    • Reset the date filter.
    • View the properties.