Switch zoning for Hitachi HUS 100 familystorage systems

Switch zoning configurations for the Hitachi HUS 100 family system include fabric zoning, target port sharing, host splitting, and controller splitting.

The Hitachi HUS 100 family system has no zoning limitations.

The Hitachi HUS 100 family systems present themselves by default to the Lenovo Storage V series system as separate controllers for each port that is zoned to the Lenovo Storage V series system. For example, if one of these storage systems has four ports that are zoned to the Lenovo Storage V series system, each port appears as a separate controller rather than one controller with four WWPNs. A given logical unit (LU) must be mapped to the Lenovo Storage V series system through all controller ports that are zoned to the Lenovo Storage V series system by using the same logical unit number (LUN).

Fabric zoning

When you zone a Hitachi HUS 100 family storage system to the Lenovo Storage V series backend ports, be sure to have multiple zones or multiple Hitachi HUS 100 family storage system and Lenovo Storage V series ports per zone to enable multipathing.

Target port sharing

The Hitachi HUS 100 family storage system can support LUN masking to enable multiple servers to access separate LUNs through a common controller port. In this setup, there are no issues with mixing workloads or server types.

Host splitting

To prevent multipathing driver incompatibility issues, avoid connecting a host to both the Lenovo Storage V series system and a Hitachi HUS 100 family system at the same time.

Controller splitting

Performance issues might be caused by splitting controllers. Ideally, configure so that the Lenovo Storage V series system has exclusive access to the controller. Hitachi HUS 100 family storage system LUNs that are mapped to the Lenovo Storage V series system cannot be mapped to other hosts. LUNs that are not presented to the Lenovo Storage V series system can be mapped to other hosts.